SKF Microlog® GX Series – Data Collector/Analyzer
SKF Microlog® GX Series – Data Collector/Analyzer
Supports the GX Series Microlog System CMXA 75
Firmware Version 4.03
User Manual Part No. 32298500-EN
Revision D
Table of Contents
Introduction to the SKF GX Series Microlog 1
Safety Messages 1-1
About This Manual 1-2
What is the GX Series Microlog System? .1-4
The GX Series Microlog Main Menu Screen 1-9
Module Management . 1-10
GX Series Microlog Buttons and Keypad . 1-12
How to Use the Buttons and Keypad 1-13
Battery Operations . 1-19
Microlog System Connections 1-22
SD Memory Card Operation . 1-27
How to Perform a Reset on Your Microlog . 1-28
Strap Attachment . 1-29
GX Series Microlog Specifications 1-29
How to Set Up Your GX Series Microlog 2
System Settings 2-1
Global Measurement Settings . 2-7
Sensor Setup 2-10
Troubleshooting . 2-13
The ROUTE Module 3
Overview .3-1
How to Download and Upload ROUTEs and
ROUTE Data with the GX Series Microlog .3-2
Selecting Operators 3-3
The Route Manager 3-3
How to Collect ROUTE Measurements .3-4
Viewing Dynamic Measurement Data . 3-10
Viewing Time Waveform Data 3-14
Viewing Multi-Channel Data . 3-17
How to Collect Process Measurements . 3-19
How to Attach Coded Notes 3-22
Speed Tagging 3-23
Using a Temporarily Attached Pickup . 3-24
Hints for Efficient Data Collection 3-25
Spectral Banding 3-26
Multi Point Automation (MPA) 3-26
How to Review Collected Data 3-28TOC – 2 SKF Microlog – GX Series
User Manual
The Analyzer Module 4
Overview .4-1
How to Collect Standard Vibration
Measurements .4-3
How to Save, View, and Delete Analyzer
Measurement Results .4-14
How to Perform Multi-Channel Measurements. 4-19
How to Measure Shaft Orbit . 4-29
How to Perform a Bump Test .4-33
How to Perform Motor Current Measurements. 4-36
Machinery Balancing Module 5
Microlog Balancing Overview 5-1
Single-Plane Balancing Overview .5-1
How to Set Up the Microlog for a Single-Plane
Procedure .5-3
How to Perform a Single-Plane Procedure 5-8
Two-Plane Balancing Procedure Overview 5-24
How to Set Up a 2 Plane Procedure 5-26
How to Perform a Dynamic 2 Plane Procedure. 5-27
How to Perform a 1-2 Plane with Prognosis
Procedure .5-38
Balancing Using the Strobe light 5-47
Data Recorder Module 6
Overview .6-1
How to Perform a Data Recorder Measurement . 6-2
Run Up / Coast Down Module 7
Overview .7-1
How to Set Up a RUCD Measurement .7-2
Recording the Measurement .7-6
Displaying Acquired Data .7-7
Saving RUCD Data 7-26
Frequency Response Function Module 8
Overview .8-1
Additional Background Information .8-1
How to Set Up an FRF Measurement 8-2
Recording the Measurement .8-7
Field Calibration 8-12
Saving FRF Data .8-13SKF Microlog – GX Series TOC – 3
User Manual
Conformance Check Module 9
Overview .9-1
How to Transfer Test Templates to the
Microlog GX .9-2
How to Set Up or Customize Conformance
Test Templates 9-4
How to Perform a Conformance Survey . 9-16
Saving Conformance Check Data . 9-22
Spindle Test Module 10
Overview 10-1
How to Transfer Test Templates to the
Microlog 10-2
How to Perform a Survey . 10-2
Spindle Tests Overview . 10-6
Survey Warning Messages .10-23
How to View Stored Test Results 10-24
How to Backup Stored Survey Results .10-25
How to Delete Stored Surveys .10-26
Idler Sound Monitor Module 11
Overview 11-1
Hardware Setup . 11-5
How to Set Up a Conveyor Idler Survey 11-11
How to Perform a Conveyor Idler Roller
Survey 11-14
Transferring, Reviewing, and Deleting Survey
Data Files .11-19
Resetting Measurement Alarm Thresholds 11-22
Non ROUTE A
Overview .A-1
Non ROUTE Mode Operations . A-1
How to Collect Pre-set Non ROUTE
Measurements .A-3
How to Collect “User” Defined Non ROUTE
Data . A-10
How to Set Up HFD Measurements A-15
How to Set Up Multi-Channel Measurements . A-16
How to Set Up a Cross Channel Phase
Measurements A-22
Multi Channel Cursor, Display Expand, and
Full Scale Adjustments . A-24
How to Review Non ROUTE Measurement
Data A-25TOC – 4 SKF Microlog – GX Series
User Manual
Field Upgrades and Accessories B
Overview .B-1
Using the Headphones and Strobe Light C
How to Use the Headphones with the GX .C-1
How to Use the Strobe Light with the GX C-2
Safety Instructions D
Instrument Installation Drawing
(090-22600-1 Rev B) D-1
Safety Instructions (090-22861-1 Rev C) D-4
Glossary of Terms
IndexSKF Microlog – GX Series 1 – 1
User Manual
Index
.
.wav file 6-1
@
@ptitude analyst 1-7
1
1-2 plane with prognosis 5-3, 5-38
1x RPM 3-12
3
30/30 rule 5-16
A
accel, pre-set measurement A-4
accel-time, pre-set measurement A-4
accessories B-1
acoustic enveloping 11-3
acquire RUCD data 7-2
acquiring data 11-14
active spectrum 7-21
activesync 1-25, 2-5, 9-2
adapter plate 11-8
alarm
status indicators 3-9
alarm indicators 3-26
bands 3-26
overall alarm 3-26
peak alarms 3-26
alarm settings 11-18
all backup option 4-17, 10-25, 10-26, 11-21
all delete option 4-18
alphanumeric keypad 1-17
analysis and reporting manager 4-1
Analysis and Reporting Manager 1-8
analysis button 11-15, 11-18
analyzer
menu 4-2
saving 4-14
analyzer module 4-1
ARM 1-8
arrow buttons 1-14, 3-6
data display screens 1-16
hierarchy list screens 1-16
main screen 1-14
setup screens 1-15
attaching strap 1-29
audible tone 11-16
audio file 6-1
audio recording 7-1, 7-7
average, balancing 5-11
averages 4-11, A-14
averaging, exponential 4-11
B
backing up 10-25
backing up stored readings 4-17
balancing 1-5, 5-1
2 plane setup 5-26
30/30 rule 5-16
correction type 5-7
estimating trial weight 5-15
manual entry 5-6
polar 5-7
prognosis 5-3, 5-38
setup 5-3, 5-4
single plane 5-8
splitting weights 5-21
strobe light 5-47
summary table 5-8
trigger 5-1
bands
beginning freq. 9-14
end freq. 9-14
labels 9-14
number of 9-13
test 9-12
battery
charging 1-19, 1-21
installation 1-19, 1-20
maintenance 1-21
replacement 1-20
replacing 1-20
temperatures 1-20
beginning freq. 9-14
bias check 3-25
bin zeroing A-15
bitmap 9-9
Bode plot 7-8
display 7-10
setup 7-8
bump test 4-33
buttons 1-13Index – 2 SKF Microlog – GX Series
User Manual
arrow 1-14
enter 1-14
function 1-14
shift 1-14, 1-17
C
cepstrum 4-5
channel control 11-10
channels
number of 4-9
chapter overview 1-3
clipped signal 7-6
coded notes 3-22
col < / > col function button 9-20, 10-6
collapse hierarchy 3-6
collecting data 3-4
color display 1-9
column, scroll 9-20, 10-6
communication
connections 1-22
set up 3-2
communications 1-25
activesync 1-25
USB 1-25
windows mobile device center 1-25
config screen 2-7
fill spectrum 3-13
frequency units 2-8
historical data collect 2-10
route ICP 2-9
configuration screen 2-7
conformance check
overview 9-1, 10-1
performing test 9-16, 10-2
saving results 9-21, 10-23
setup tabs 9-6
conformance check setup software 9-1, 9-4,
10-1
connections 1-22
coupling 1-23
disconnecting 1-23
correction type, balancing 5-7
coupling A-12
CPM 4-8, 4-10
cross channel phase A-22
data collection A-22
display screen A-23
measurement setup A-22
phase tables A-24
cursor
multi channel 4-28, A-24
peak 3-14
two channel 3-18
cursor mode 3-13
D
data
transfer 3-2
data collection 3-25
cross channel phase A-22, A-23
MPA measurements 3-27
multi spectrum A-17
multi time waveform A-17
orbit A-8
process measurements 3-19
retaking measurements 3-25
route 3-4
skipping measurements 3-25
data display
expand 3-18, 4-28, A-24
full scale adjustments 3-18, 4-28, A-24
multi channel cursor 4-28, A-24
phase tables A-24
two channel cursor 3-18
date format 2-5
date setting 2-5
db ref units 4-11
db reference 4-11
default function button 5-5
delete
measurement results 4-15
measurement setup 4-15
delete saved meas. 4-18
deleting meas. 7-26, 10-26
detection
analyzer 4-11
conf. checker 9-14
dimmed icons
hiding 1-10, 1-11
directions, test 9-7
display format A-11
display screen
printing 1-18
display y axis 4-10
download 1-22
downloading 3-2
dynamic measurements 3-10
review 3-28SKF Microlog – GX Series Index – 3
User Manual
spectral display screen 3-10
time waveform display screens 3-14
E
end freq. 9-14
enter buttons 1-14
enveloped accel, pre-set measurement A-5
error messages 3-24
estimate trial weight 5-15
expand hierarchy 3-5, 3-6
exponential averaging 4-11
ext. trig slope A-15
F
FFT spectral banding 3-26
FFT spectrum 9-13, 9-21
field analysis features 3-13
fill spectrum 3-13
filter A-13
analyzer 4-10
firmware version number 1-9, 1-12, 1-14,
10-2
fixed weight 5-7
fmax A-13
actual values 3-3, A-13
font size 2-5
free text note 11-17
freq range 4-10, 6-7
FRF
calibration 8-12
equipment setup 8-2
function buttons 8-5
hammer 8-2
recall 8-7
save settings 8-5
setup 8-5
taking data mode 8-9
function button
default 5-5
function buttons 1-14, 2-1, 2-2, 2-11
about button 1-12
FRF 8-5
help button 1-12
idler sound monitor screen 11-11, 11-15
manual data entry display screen 3-21
non-route mode A-2
orbit display screen A-9
overview 1-12
process display screen 3-20
route 3-6
route manager 3-3
spectral display screen 3-12
time waveform display screen 3-16
user screen A-10
G
gE, pre-set measurement A-5
global measurement settings 2-7
grade bands 9-6
grade boundaries 9-6
grade labels 9-6, 9-12
grades
bands 9-12
boundaries 9-15
labels 9-12
levels 9-15
number of 9-12
graph scaling adjustment, y-axis 3-14
graphic 9-18, 10-4
grid 3-13
grid view 3-13
GX Series Microlog system 1-4
H
hammer 8-2
hammer test 4-33
hard reset 1-28
harmonic activity indicator 11-3
harmonic marker 3-13
harmonic markers 3-14, 4-7
hazardous area 1-27, 10-25
headphone volume controls 11-10
headphones 1-18, 3-9, 11-2, 11-10, C-1
setting volume 11-10
help
button 1-12
HFD A-5, A-13, A-15
hide dimmed icons 1-10, 1-11
hide icons 1-10, 1-11
hierarchy 3-1
collapse 3-6
expand 3-5, 3-6
navigation 3-5
high res, pre-set measurement A-3
high-pass filter A-13Index – 4 SKF Microlog – GX Series
User Manual
historical data
configure 2-10
review 3-32
save 3-9
home screen 1-14, 10-2
Hz 4-8, 4-10
I
icons
hide/show 1-10, 1-11
ICP 2-9
error 9-21, 10-23
idler sound monitor
adapter plate 11-8
function buttons 11-11, 11-15
led indications 11-13
measurement types 11-3
microphone 11-6
notes 11-5
optimal conditions 11-14
parabolic reflector 11-6
independent autoranging 4-29, A-24
indicators, LCD 1-5
initialize 2-5
initializing DAQ 11-14
input channel A-12
input devices 1-5
internal drive 7-5, 8-7
Internal drive 6-7
K
keypad 1-17
alphanumeric 1-17
entering letters 1-17
entering numbers 1-17
Kurtosis 11-3
L
language 2-6
last point of route 3-10
LCD display 1-9
LCD indicators 1-5
led indications, idler sound monitor 11-13
license modules 1-12
linear 4-10
lines resolution 4-11
lines/samples A-13
live time waveform 6-3
location no. 9-15
logarithmic 4-10
M
machine picture 9-6, 9-9
machine speed 2-8
main screen 1-9
manual entry, balancing calculations 5-6
manual function button 3-21
mark button 11-15
markers, harmonic 3-14
max. rec. time 6-7, 7-5, 8-7
maximum acq. time 7-5
measurements
acoustic 11-3
memory card 1-27
memory operations 2-5
delete all routes 2-5
initialize 2-5
troubleshooting 2-13
microlog 1-4
microphone 11-6
mobile device 9-2
mode – RUCD 7-5
module
model versions 1-6
spindle test 10-1
module manager 1-10, 1-11
modules
hide/show 1-10, 1-11
license 1-12
purchase 1-12
motor current measurement 4-36
MPA measurements 3-23, 3-26
data collection 3-27
review 3-31
multi channel 4-9, 6-7, A-12
cross channel phase A-22
cursor 4-28, A-24
display expand 4-28, A-24
full scale adjustments 4-28, A-24
route mode 3-17
spectrum data collection A-17
spectrum setup A-17
time waveform data collection A-17
time waveform setup A-17
multi measurements
collection A-17
setup A-17SKF Microlog – GX Series Index – 5
User Manual
multi spectrum
measurement setup A-17
triax 4-28, A-21
two channel spectrum A-18
two channel spectrum/time A-20
two channel time A-19
multi time waveform
measurement setup A-17
multi-channel measurements 4-19
multi-point automation See MPA
measurements
mute 11-10
N
non-route
function buttons A-2
pre-set measurements A-3
review A-25
triax displays 4-28, A-21
two channel spectrum A-18
two channel spectrum/time A-20
two channel time A-19
user screen A-10
user-defined measurements A-10
normalization 11-4, 11-16
note button 11-17
notes, coded 3-22
number of bands 9-13
number of components 5-7
Nyquist plot 7-11
display 7-12
setup 7-11
O
operator, selecting 3-3
opposite, pre-set measurement A-3
orbit 4-19, A-5
data collection A-8
data review 3-30
overview 4-29, A-5
route mode 3-18
setup A-6
setup screen A-6
orbit setup A-6
coupling A-6
ext. trigger slope A-7
level A-7
sensitivity A-7
trigger A-7
units A-6
overall vibration 6-3
overlap 4-11, A-14
overload
clearing 3-25
signal 3-25
P
parabolic reflector 11-6
pause recording 6-4
peak cursor 3-14
phase 4-7, 4-10
phase tables A-24
phase, cross channel A-22
pickup 3-24
picture 9-18, 10-4
point information A-26
polar 5-10
polar correction 5-7
post-process 6-1
power button 1-14
power cycle, automatic 1-14, 3-13
power spectrum 4-5
power supply/battery charger 1-19, 1-20
pre-set measurements A-3
acceleration A-4
acceleration-time A-4
enveloped acceleration A-5
hfd A-5
high resolution A-3
opposite A-3
orbit A-5
same A-3
velocity A-4
printing
from display 4-16, 10-24
screens 1-18
test results 4-16, 10-24
process measurements
data collection 3-19
manual data entry 3-21
review 3-34
review screen 3-34
processing time – RUCD 7-2
prognosis 5-3, 5-38
message 5-43
pulses/rev 7-5
purchase modules 1-12Index – 6 SKF Microlog – GX Series
User Manual
R
recall 5-3, 6-2, 7-3, 7-26, 8-4, 8-7, 11-12
recalling a setup 11-19
recorder
overview 6-1
preview mode 6-3
recording mode 6-8
recording time 6-8
recording, pause 6-4
reference point, speed 3-23
reset, hard 1-28
resolution 4-11
resume mode 1-14
resume recording 6-4
review 3-28
dynamic measurements 3-28
historical data 3-32
MPA measurements 3-31
non-route A-25
orbit data 3-30
process measurements 3-34
spectral display screen 3-28, A-26
three channel in route 3-31
triax in route 3-31
two channel in route 3-31
review meas. 7-26
review process screen 3-34
reviewing test results 10-24
rotor mass 5-14
route 3-1
delete all 2-5
font 2-5
function buttons 3-6
hierarchy 3-4
hierarchy list navigation 3-5
multi channel data 3-17
orbit data 3-18
route module 3-1
status 3-9
RPM
1x RPM 3-12
RUCD
led 7-4
mode 7-5
processing time 7-2
setup 7-4
start – stop speed 7-5
state 7-6
taking data mode 7-6
run-up coast-down 6-1, 7-1
S
same, pre-set measurement A-3
samples/lines A-13
save
meas. results 4-14
meas. setup 4-12, 4-14, 4-22, 4-32, 4-36,
4-38
save button 11-14
saving meas. 7-26
saving screens 1-18
saving settings 11-14
saving test results 9-21, 10-23
saving test template 9-16
scroll columns 9-20, 10-6
SD card 1-9, 1-27, 4-17, 6-7, 7-5, 8-7,
10-25, 11-21
operation 1-27
printing screens 1-18
selecting operators 3-3
sensitivity A-13
sensor
disconnecting 3-10, 3-25
orientation 9-7, 9-15
setup 2-10
type 4-9
variable 4-9
sensor setup screen 2-10
sensor type
conf. checker 9-6
serial number 1-12
settling 2-8
delay 2-8
setup screen 2-1, 2-2
date format 2-5
date/time 2-5
default units 2-2
memory 2-5
route memory 2-2
timeout 2-2
setup, balancing 5-4
shift button 1-14, 1-17
shift key 2-1
show icons 1-10, 1-11
SKF title screen 1-9, 1-14, 10-2
skip function button 9-19, 10-6
skip test position 9-19, 10-6SKF Microlog – GX Series Index – 7
User Manual
software
conf. check setup 9-1, 10-1
specify RPM
database A-7, A-23
spectral display A-8, A-23
type in A-8, A-23
spectral banding 3-26
spectral data 3-10
spectral display screen 3-10
fill spectrum 3-13
multi channel 3-17
spectrogram 7-23
display 7-23
display status area 7-26
setup 7-23
Speed
1x RPM 3-12
speed ratio 3-23
speed reference point 3-23
speed tagging 3-23
error messages 3-24
spindle
balancing test 10-23
bearing condition test 10-9
belt tension test 10-18
clamp force test 10-13
EM distance test 10-16
imbalance test 10-6
mechanical condition test 10-8
module 10-1
nose run-out test 10-11
resonant frequency test 10-21
speed accuracy test 10-20
test
templates 10-1
start button 11-14
stop acquisition 4-11
strap attachment 1-29
strobe light C-2
summary, balancing 5-8
suspend mode 1-14
system settings 2-1
T
table – RUCD 7-13
display 7-14
setup 7-13
table of peaks 4-5
taking data mode 8-8
test template 9-1, 10-1
copy 9-3
custom 9-2, 10-1
folders/icons 9-17, 10-4
location 9-3
pre-configured 9-1, 10-1
saving 9-16
selection 9-17, 10-4
setup 9-4
spindle 10-1
transfer 10-2
transfer to AX 9-2
text note 11-17
three channel
review in route 3-31
time remaining 6-4
time setting 2-5
time waveform 6-1
time waveform data 3-14
time zone 2-5
title screen 1-14, 10-2
tone 11-16
traffic light indicator 11-3
transfer 3-2
transfer test template 9-2, 10-2
transient capture 6-1, 7-1
trial weight 5-14
estimate 5-15
triax 3-17
non-route 4-9, 4-28, A-12, A-21
review in route 3-31
triax measurement 4-28
triaxial measurements 4-9, A-12
trigger 5-1, 5-6, A-7
trigger level A-15
triggerless operation A-25
troubleshooting 9-21, 10-23
troubleshooting, bias check 3-25
troubleshooting, memory operations 2-13
two channel
cursor 3-18
display expand 3-18
full scale adjustments 3-18
independent autoranging 4-29, A-24
non-route A-18, A-19
review in route 3-31
spectrum A-18
spectrum/time waveform A-20
time waveform A-19
triggerless operation A-25Index – 8 SKF Microlog – GX Series
User Manual
two channel recording 6-3
type A-14
types of measurements A-3
U
unit ID number 1-12
units 2-2, 4-8, 4-10, A-12
conf. checker 9-14
upgrades B-1
upload 1-22
uploading 3-2
USB 1-19, 1-23, 9-2
communications 1-25
driver 1-25
user function button A-2
user manual conventions 1-2
user screen A-10
function buttons A-10
user, selecting 3-3
user-defined measurement options A-11
averages 4-11, A-14
bin zeroing A-15
change name A-11
coupling A-12
display format A-11
ext. trig. slope A-15
fmax A-13
high-pass filter A-13
input channel A-12
level A-15
lines/samples A-13
overlap A-14
sensitivity A-13
type A-14
units A-12
window 4-12, A-14
user-defined non-route measurements A-10
V
variable sensor type 4-9
velocity, pre-set measurement A-4
version number 1-14, 10-2
vibration threshold 5-7
view 3-13
grid 3-13
options 3-13
view signal 4-10
volume control 11-10
W
warning messages 9-21, 10-23
waterfall plot 7-15
display 7-16
display status area 7-21
setup 7-15
wav file 7-1, 7-7
wind baffle 11-9
window 4-12, A-14
windows mobile device center 1-25
X
x axis units 4-8, 4-10
Y
y axis units 4-10
y-axis display 4-11
y-axis graph scaling adjustment 3-14
كلمة سر فك الضغط : books-world.net
The Unzip Password : books-world.net
تعليقات